Engineered in Germany since 1961 — IP66-rated enclosures, NEBS Level 3 cabinets, and integrated cooling systems protecting the infrastructure that connects the world.
From indoor server racks to weatherproof outdoor enclosures — modular systems designed for every network environment.
Purpose-built enclosure systems for every segment of the telecom value chain.
NEBS Level 3 compliant cabinets and outdoor enclosures for central offices, edge nodes, and cell tower equipment shelters serving major telecom operators.
High-density server racks with integrated power distribution, hot/cold aisle containment, and liquid cooling support for up to 30kW per rack.
Pre-configured, self-contained micro data center enclosures deployable in retail, manufacturing, and remote locations within 48 hours.
Ruggedized enclosures for harsh industrial environments — chemical-resistant coatings, seismic zone 4 rated, -40°C to +55°C operating range.
Deployed across carrier networks, data centers, and critical infrastructure on six continents.
Telecommunications — Fixed-Line Infrastructure
A Tier-1 European fixed-line operator needed to consolidate 340 central offices from legacy open-frame racks to NEBS Level 3 enclosed cabinets within 24 months to meet updated fire safety regulations. Rittal delivered 12,000 TS 8 cabinets with integrated smoke detection and FM-200 suppression interfaces. The standardized modular design enabled local installation crews to complete each site in 3 days versus the 10-day average with the previous vendor, finishing the rollout 4 months ahead of the regulatory deadline.
Telecommunications — 5G Wireless Infrastructure
A mobile network operator rolling out sub-6 GHz 5G across 45 metropolitan areas required IP66-rated outdoor enclosures that could house radio units, power supplies, and fiber distribution in a compact street-level footprint. Rittal supplied 8,500 compact outdoor cabinets (600mm × 600mm × 1200mm) with integrated heat exchangers rated for −30°C to +50°C. The pre-wired, pre-tested units reduced on-site installation time from 6 hours to 90 minutes per node, accelerating the operator’s coverage target by 5 months.
Cloud Computing — Hyperscale Data Centers
A global cloud provider expanding a 120MW data center campus in Northern Europe required high-density rack infrastructure supporting 30kW per cabinet with rear-door liquid cooling for GPU-intensive AI training workloads. Rittal delivered 4,200 VX25 racks with integrated LCP (Liquid Cooling Package) units, modular busbar PDU, and DCIM sensors connected via open REST API. The standardized rack design achieved a Power Usage Effectiveness (PUE) of 1.15, contributing to the campus meeting its carbon-neutral operations target.
Our commitment to environmental responsibility is built into every product we design and every factory we operate.
Blue e+ cooling technology reduces energy consumption by up to 75% compared to conventional climate control units through speed-controlled compressor inverters.
All 18 manufacturing facilities operate under ISO 50001 energy management — we reduced our own production energy consumption by 32% since 2018.
92% recyclable materials by weight. Powder-coated steel enclosures achieve a 25+ year service life, minimizing replacement waste across global deployments.
Our engineering team is ready to design the right enclosure solution for your deployment — from single cabinets to nationwide rollouts.